Contract award record
GB-Swindon: UKRI-2291 Radiation Monitors for Gamma Detection Outside Concrete Test Facility Shielding
Notice details
- Published
- Category
- goods
- Buyer region
- South West
- Source
- View official notice
Public buyer and contract winner
Award value£72,047
- AwardedCompleted
- StartCompleted
- EndCompleted
Work description
This tender requires the design, manufacture, quality control testing and calibration of an initial eight (8), fixed ionising radiation monitors and applicable control software with the option of purchasing an additional four (4) in the subsequent three years.
The intended use for these monitors is in fixed occupied locations outside the primary shielding. In these locations, radiation is heavily attenuated by the accelerator components and shielding structures. The shielding has been designed such that dose rates external to the shield walls of the accelerator should be below 1 µSv/h, however, unexpected beam losses can occur which could lead to unplanned, elevated dose rates above the design criteria outside the enclosure. The purpose of these monitors is to detect dose rates at systematically selected locations around the accelerator and either warn those in the vicinity or terminate power to the accelerator depending on the magnitude of the detected dose rate.
Additional information: Procurement Contract Transparency Data: Redacted contract documents will be made available within the next 30 days on the UKRI website at: https://www.ukri.org/about-us/procurement-contract-transparency-data/